# pwd(切到软件目录) /usr/local/infobright-4.0.6-x86_64# ./postconfig.sh(第一次运行postconfig.sh,更改IEE数据库的数据目录) Infobright post configuration--------------------------------------Using postconfig you can:--------------------------------------(1) Move existing data directory to other location,(2) Move existing cache directory to other location,(3) Configure server socket,(4) Configure server port,(5) Relocate datadir path to an existing data directory.Please type "y" for option that you want or press ctrl+c for exit.Current configuration:--------------------------------------Current config file: [/etc/my-ib.cnf]Current brighthouse.ini file: [/usr/local/infobright-4.0.6-x86_64/data/brighthouse.ini]Current datadir: [/usr/local/infobright-4.0.6-x86_64/data]Current CacheFolder in brighthouse.ini file: [/usr/local/infobright-4.0.6-x86_64/cache]Current socket: [/tmp/mysql-ib.sock]Current port: [5029]--------------------------------------(1) Do you want to copy current datadir [/usr/local/infobright-4.0.6-x86_64/data] to a new location? [y/n]:yGive new datadir path (e.g. /opt/datadirnewpath/data):/ieedata/data(2) Option to change CacheFolder is disabled when option 1 is chosen!(3) Do you want to change current socket [/tmp/mysql-ib.sock]? [y/n]:n(4) Do you want to change current port [5029]? [y/n]:n(5) Relocation is disabled when options 1-4 are chosen!--------------------------------------Datadir(/usr/local/infobright-4.0.6-x86_64/data) is going to be copied to /ieedata/data--------------------------------------Please confirm to proceed? [y/n]:yCopying /usr/local/infobright-4.0.6-x86_64/data to /ieedata/data ...is done.You can now remove/backup your old /usr/local/infobright-4.0.6-x86_64/data ...Done! # ./postconfig.sh(第二次运行postconfig.sh,更改IEE数据库的cache目录) Infobright post configuration--------------------------------------Using postconfig you can:--------------------------------------(1) Move existing data directory to other location,(2) Move existing cache directory to other location,(3) Configure server socket,(4) Configure server port,(5) Relocate datadir path to an existing data directory.Please type "y" for option that you want or press ctrl+c for exit.Current configuration:--------------------------------------Current config file: [/etc/my-ib.cnf]Current brighthouse.ini file: [/ieedata/data/brighthouse.ini]Current datadir: [/ieedata/data]Current CacheFolder in brighthouse.ini file: [/usr/local/infobright-4.0.6-x86_64/cache]Current socket: [/tmp/mysql-ib.sock]Current port: [5029]--------------------------------------(1) Do you want to copy current datadir [/ieedata/data] to a new location? [y/n]:n(2) Do you want to move current CacheFolder [/usr/local/infobright-4.0.6-x86_64/cache] to a new location? [y/n]:y Give new CacheFolder path:/ieedata/cache(3) Do you want to change current socket [/tmp/mysql-ib.sock]? [y/n]:n(4) Do you want to change current port [5029]? [y/n]:n(5) Relocation is disabled when options 1-4 are chosen!--------------------------------------New CacheFolder is going to be /ieedata/cache--------------------------------------Please confirm to proceed? [y/n]:yCreating new cachedir /ieedata/cache ...is done.Done!
# /etc/init.d/mysqld-ib start# mysql-ibWelcome to the MySQL monitor.Commands end with ; or g.Your MySQL connection id is 3Server version: 5.1.40 build number (revision)=IB_4.0.6_r16086_16275(iee - commercial) (static)Type "help;" or "h" for help. Type "c" to clear the current input statement.mysql> grant all privileges on *.* to "root"@"%" identified by "123456"WITH GRANT OPTION;Query OK, 0 rows affected (0.00 sec)mysql> flush privileges;Query OK, 0 rows affected (0.00 sec)mysql>
⑦用户利用navicate工具连接到IEE数据库,进行建库建表,字符集的选择utf-8:
character set : utf8 -- UTF-8 Unicodecollation : utf8_bin本文永久更新链接地址